Application du variateur de fréquence Harsvert dans ventilateur brasseur d'air

Application du variateur de fréquence Harsvert dans ventilateur brasseur d'air
2009-12-15 13:52:29

I. Introduction

Tongli Cement Co., Ltd a été fondé en 1995 et est doté de deux lignes de production, avec une productivité journalière de 2500t et une productivité annuelle de 2 000 000t. En 2006, Tongli cement plant s’est procuré un Harsvert-A06/150 pour ajuster la vitesse. L’entraînement à fonctionné stablement depuis qu’il a pris en charge les opérations (janvier 2007) et l’économie en énergie est considérable.
II. Energy-saving effect

Circulating fan is driven by wire-wound motor. Its rated power is 6kV/1250kW. Before using VFD, air flow was adjusted by valve and there is much power loss on valve. Meanwhile, because valve was adjusted frequently, reliability of valve was not good, which affected system stability. After using VFD ( short connecting rotor winding), motor speed is adjusted by VFD. There is no need to adjust valve frequently and valve opens at a large scope.

Data in the site:

item

Before modification

After modification

Total material volume (t/h)

220

200

Given speed of VFD (r/min)

1000

820

Grinding head pressure(Pa)

13

160

Grinding tail pressure(Pa)

1000

1100

Motor current A

55

35

Noise

67

67

Outlet pressure(Pa)

2300

1800

Outlet temperature (℃)

78

52

We can see that motor current is lower after reconstruction with VFD and energy is saved a lot. 

 III. Characters of Harsvert VFD

Model

Harsvert-A06/150

Rated capacity

1565KVA

Rated current

150A

Rated voltage

6kV

Output frequency

0~50Hz

Motor power

1250kW

Acceleration/deceleration time

0~3200s

Over load capacity

120% for 60s, 150% for 3s, 200% immediately

Protection

Over voltage, low voltage, over current, over heat, earth, lack phase and so on.



IV Advantages
When motor starts, current increases from zero and will be not over rated current. So VFD avoids big current impact when motor starts, decreases maintaince, improves system safety.

V. Conclusion
Adjusting speed by VFD is not only easy and convenient but also saves much energy. It improves system safety and manufacture process.

Produits relatifs
Commentaires
Autres Produits
Envoyer un message
Envoyer un message